PMODE=0, WE=0, TRIGM=0, INV=0, COS=0, OPE=0, SE=0, EN=0
CMP Control Register 1
| EN | Comparator Module Enable 0 (0): Analog Comparator is disabled. 1 (1): Analog Comparator is enabled. |
| OPE | Comparator Output Pin Enable 0 (0): CMPO is not available on the associated CMPO output pin. 1 (1): CMPO is available on the associated CMPO output pin. |
| COS | Comparator Output Select 0 (0): Set the filtered comparator output (CMPO) to equal COUT. 1 (1): Set the unfiltered comparator output (CMPO) to equal COUTA. |
| INV | Comparator INVERT 0 (0): Does not invert the comparator output. 1 (1): Inverts the comparator output. |
| PMODE | Power Mode Select 0 (0): Low-Speed (LS) Comparison mode selected. In this mode, CMP has slower output propagation delay and lower current consumption. 1 (1): High-Speed (HS) Comparison mode selected. In this mode, CMP has faster output propagation delay and higher current consumption. |
| TRIGM | Trigger Mode Enable 0 (0): Trigger mode is disabled. 1 (1): Trigger mode is enabled. |
| WE | Windowing Enable 0 (0): Windowing mode is not selected. 1 (1): Windowing mode is selected. |
| SE | Sample Enable 0 (0): Sampling mode is not selected. 1 (1): Sampling mode is selected. |